M.C.MILLER

Thứ Sáu, 26 tháng 6, 2015

14627, AccuRef30 Copper/Copper Sulfate Permanent Reference Electrode, MCMILLER Viet Nam, Pitesco

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Email :      trinh@pitesco.com
Website:   www.pitesvietnam.com                                                       
                www.mcmiller.com    
Service and Support
Phone: 0914 738 179
Email: trinh@mcm.com

AccuRef30 Copper/Copper Sulfate Permanent Reference Electrode

pdf
pdf
pdf
Item Number:14627
Price:$Vui lòng gọi
Quantity:
Continue Shopping
FEATURES & BENEFITS

•  Electrodes are buried directly with native soil backfill – no need for composite backfills. Note: These products are suitable for use in neutral soil having a chloride ion content <500ppm. [AccuRef Silver/Silver Chloride electrodes are recommended for use in higher chloride ion content soils]

•  Depressed electrolyte freezing temperature of -20°C allows electrodes to experience a deep frost without freezing and cracking.

•  Design life of 30 years (please see “Important Notes” below)

•  Large electrical contact area (electrically active surface area) having hygroscopic characteristics promotes good electrode-to-soil electrical contact. [Note: Soil moisture content is a requirement for a buried metallic structure potential reading versus any permanently installed reference electrode, which means that readings in ultra-dry soil are not possible]

Important Notes:

1) These products must be installed according to the installation instructions provided
2) These products are not guaranteed to maintain their calibration in all soil environments and it is incumbent on the customer to test their soil for chloride ion content and for the presence of any other potential chemical contaminants prior to installation of these products.The M. C. Miller Company has not tested these products with regard to the effects of specific (potential) chemical contaminants on their calibration.
3) These products are not designed for submersion applications.

15150, RE-5 Field Kit, MCMILLER Viet Nam, Pitesco

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Email :      trinh@pitesco.com
Website:   www.pitesvietnam.com                                                       
                www.mcmiller.com    
Service and Support
Phone: 0914 738 179
Email: trinh@mcm.com

RE-5 Field Kit

pdf
Item Number:15150
Price:$Vui lòng liên hệ
Quantity:
Continue Shopping
Kit comes in a leak proof case and contains: (1) RE-5 Portable Electrode (15108)
(1) RE-5 Plug Assembly (15403)
(1) 4 Oz. Bottle of Copper Sulfate Antifreeze Solution
(1) 6 Oz. Bottle Copper Sulfate Crystals
(1) Spare RE-5 Protective Cap (15800)
(4) Spare O-Rings for Plug Assembly (ELE016)

14555, IonX RE-5C Type Electrode, MCMILLER Viet Nam, Pitesco

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Email :      trinh@pitesco.com
Website:   www.pitesvietnam.com                                                       
                www.mcmiller.com    
Service and Support
Phone: 0914 738 179
Email: trinh@mcm.com

IonX RE-5C Type Electrode

pdf
pdf
pdf
pdf
Item Number:14555
Price:$Vui lòng gọi
Quantity:
Continue Shopping
Note: In order to ensure proper operation and calibration of your IonX 5 or 5C, the manufacture and calibration of your electrodes are not completed until your order is placed. Please allow 2 -3 days before items are shipped from our manufacturing facility. Your choice of shipping method will be used once your order is ready to ship. 

Package contents:


•  IonX Portable Reference Electrode
•  Electrode Calibration Certificate
•  “Derivation of Electrode Potential Value” Document
•  Instructions & Maintenance
•  2 oz Squeeze Bottle of Electrode Solution for “Top-Ups”

Features & Benefits:


•  No copper sulfate solution leakage (“Green” Electrodes)
•  Half-cell cannot be contaminated
•  No need to handle, store or dispose of hazardous copper sulfate crystals or copper sulfate anti-freeze solutions
•  Electrodes arrive “ready-to-use” – no need to prepare chemicals etc. in the field.
•  All IonX Portable Electrodes are calibrated at the factory and are shipped with a certificate of calibration.
•  Electrode potentials are in the range 316mV ±10mV at 25°C versus Standard Hydrogen Electrode (SHE)
•  Electrodes can be stored at temperatures down to -20oC
•  Electrodes have the same fittings as conventional M. C. Miller portable electrodes (for connection to standard canes and electrode extensions). The robust ceramic plugs are customized for IonX electrodes and replacement plug assemblies can be ordered when required.

Certification:


IonX Portable Electrodes are in a “ready-to-use” state upon completion of the manufacturing process and their electrode potentials are measured at the factory, prior to shipping. A certificate of calibration is issued for each electrode which, in addition to indicating the electrode potential as measured at the factory, presents the certification date and the expiration date, which is 12 months beyond the date of certification. IonX Portable Electrodes can be returned annually to the factory for a calibration “check-up”.

Calibration "Check-up" Service:


As is the case for other equipment items, such as voltmeters, for which annual calibration checking is suggested, M. C. Miller offers a calibration check-up service for IonX Portable Reference Electrodes. Please call for the current service price, which includes a new 12 month certificate of calibration. An electrode will only be issued a calibration certificate if its electrode potential falls in the range 316mV +/- 10mV, versus the Standard Hydrogen Electrode (SHE). Should the external ceramic plug require replacement in order to bring an electrode into calibration, the customer would be informed and the cost of a replacement plug would be added to the service cost.

Processing time at the M. C. Miller facility will be 5-10 business days, depending on the condition of the electrode as-received, for the re-calibration service. Shipping costs are the customer's responsibility. A Return Merchandise Authorization (RMA) number is required to accompany a returned electrode and a RMA number can be obtained from our sales department.

A word about calibration checking

M. C. Miller’s Non-Porous Plug Technology:


The “active” (half-cell) solution in an IonX Portable Electrode (saturated copper sulfate solution) is contained in a sealed unit that incorporates a non-porous, ionically-conducting plug (see MP Articles for details).

14620, AccuRef20 Silver/Silver Chloride Permanent Reference Electrode, MCMILLER Viet Nam, Pitesco

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Email :      trinh@pitesco.com
Website:   www.pitesvietnam.com                                                       
                www.mcmiller.com    
Service and Support
Phone: 0914 738 179
Email: trinh@mcm.com

AccuRef20 Silver/Silver Chloride Permanent Reference Electrode

pdf
pdf
pdf
Item Number:14620
Price:$Vui lòng gọi
Quantity:
Continue Shopping
FEATURES & BENEFITS

•  Electrodes are buried directly with native soil backfill – no need for composite backfills

•  Electrodes can be used in chloride ion containing soils, due to the use of a saturated chloride filling solution (please see the Specifications section for details)

•  Depressed electrolyte (filling solution) freezing temperature of -20°C allows electrodes to experience a deep frost without freezing or cracking

•  Design life of 20 years (please see “Important Notes” below)

•  Large electrical contact area (electrically active surface area) having hygroscopic characteristics promotes good electrode-to-soil electrical contact. [Note: Soil moisture content is a requirement for a buried metallic structure potential reading versus any permanently installed reference electrode, which means that readings in ultra-dry soil are not possible]

Important Notes:

1) These products must be installed according to the installation instructions provided
2) These products are not guaranteed to maintain their calibration in all soil environments and it is incumbent on the customer to test their soil for the presence of any potential chemical contaminants prior to installation of these products. The M. C. Miller Company has not tested these products with regard to the effects of specific (potential) chemical contaminants on their calibration.
3) These products are not designed for submersion applications.

“A Guide to Understanding Reference Electrode Readings”, (Materials Performance, September 2009 issue)

14550, IonX RE-5 Type Electrode, MCMILLER Viet Nam, Pitesco

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Email :      trinh@pitesco.com
Website:   www.pitesvietnam.com                                                       
                www.mcmiller.com    
Service and Support
Phone: 0914 738 179
Email: trinh@mcm.com

IonX RE-5 Type Electrode

pdf
pdf
pdf
pdf
Item Number:14550
Price:$Vui lòng gọi.
Quantity:
Continue Shopping
Note: In order to ensure proper operation and calibration of your IonX 5 or 5C, the manufacture and calibration of your electrodes are not completed until your order is placed. Please allow 2 -3 days before items are shipped from our manufacturing facility. Your choice of shipping method will be used once your order is ready to ship. 

Package Contents:


•  IonX Portable Reference Electrode
•  Electrode Calibration Certificate
•  “Derivation of Electrode Potential Value” Document
•  Instructions & Maintenance
•  2 oz Squeeze Bottle of Electrode Solution for “Top-Ups”

Features & Benefits:


•  No copper sulfate solution leakage (“Green” Electrodes)
•  Half-cell cannot be contaminated
•  No need to handle, store or dispose of hazardous copper sulfate crystals or copper sulfate anti-freeze solutions
•  Electrodes arrive “ready-to-use” – no need to prepare chemicals etc. in the field.
•  All IonX Portable Electrodes are calibrated at the factory and are shipped with a certificate of calibration.
•  Electrode potentials are in the range 316mV ±10mV at 25°C versus Standard Hydrogen Electrode (SHE)
•  Electrodes can be stored at temperatures down to -20oC
•  Electrodes have the same fittings as conventional M. C. Miller portable electrodes (for connection to standard canes and electrode extensions). The robust ceramic plugs are customized for IonX electrodes and replacement plug assemblies can be ordered when required.

Certification:


IonX Portable Electrodes are in a “ready-to-use” state upon completion of the manufacturing process and their electrode potentials are measured at the factory, prior to shipping. A certificate of calibration is issued for each electrode which, in addition to indicating the electrode potential as measured at the factory, presents the certification date and the expiration date, which is 12 months beyond the date of certification. IonX Portable Electrodes can be returned annually to the factory for a calibration “check-up”.

Calibration "Check-up" Service:


As is the case for other equipment items, such as voltmeters, for which annual calibration checking is suggested, M. C. Miller offers a calibration check-up service for IonX Portable Reference Electrodes. Please call for the current service price, which includes a new 12 month certificate of calibration. An electrode will only be issued a calibration certificate if its electrode potential falls in the range 316mV +/- 10mV, versus the Standard Hydrogen Electrode (SHE). Should the external ceramic plug require replacement in order to bring an electrode into calibration, the customer would be informed and the cost of a replacement plug would be added to the service cost.

Processing time at the M. C. Miller facility will be 5-10 business days, depending on the condition of the electrode as-received, for the re-calibration service. Shipping costs are the customer's responsibility. A Return Merchandise Authorization (RMA) number is required to accompany a returned electrode and a RMA number can be obtained from our sales department.

A word about calibration checking.

M. C. Miller’s Non-Porous Plug Technology:


The “active” (half-cell) solution in an IonX Portable Electrode (saturated copper sulfate solution) is contained in a sealed unit that incorporates a non-porous, ionically-conducting plug (see MP Articles for details).